  • c11.jpg

Three-skirt structure: The insulator's main insulating body adopts a three-skirt structure, with a hat-shaped head and the first, second, and third skirts arranged axially downwards. All three skirts are inclined downwards and have drip edges. This design gives the insulating body a self-cleaning anti-fouling function, preventing flashover.

Keywords:

UG210B170/550T 20R

Product Details

Structural Features

Three-skirt structure: The insulating body of the insulator adopts a three-skirt structure, with the first skirt, the second skirt, and the third skirt arranged axially downward from the hat-shaped head. All three skirts are inclined downward and have drip edges. This design gives the insulating body a self-cleaning function, preventing flashover. The maximum skirt extension of the first skirt is greater than that of the second skirt, and the maximum skirt extension of the second skirt is greater than that of the third skirt. This arrangement effectively reduces the fouling on the second and third skirts, which are more difficult to clean, improving the self-cleaning effect of the insulator.

Umbrella rib design: The first skirt includes the first, second, and third umbrella ribs arranged from left to right. The three umbrella ribs are set downward, which can further increase the creepage distance of the insulator, prevent creepage, and improve the performance against voltage surges. Several grooves are provided on the side of the third umbrella rib close to the axial center to increase the contact area with the adhesive, enhance the connection stability with the second skirt, and improve the mechanical strength.

Other structures: The lower skirt edge of the third skirt is an arc-shaped protrusion formed from the bottom upward, and the upper skirt edge is an arc-shaped recess formed from the bottom upward. Compared with the linear structure, this arrangement can increase the creepage distance of the insulator. Multiple rows of concave-convex textures are provided on the inner surface of the disc-shaped skirt opposite the steel foot to enhance the connection stability between the disc-shaped skirt and the steel foot; a semiconductor glaze is also provided on its surface to keep the surface of the disc-shaped skirt dry and make the surface voltage distribution more uniform, thereby maintaining a higher flashover voltage. In addition, it includes a steel cap and a steel foot. The steel cap is fitted on the hat-shaped head, and the steel foot is set in the accommodating groove. The insulator and the steel cap, and the insulator and the steel foot are bonded and fixed by an adhesive.

Performance Characteristics

Good antifouling performance: The three-umbrella structure design makes the underside smooth, without ridges, and open, with good self-cleaning performance in wind and rain, and a low natural fouling rate. In environments with high dust content, the advantages of the umbrella-shaped structure are even more pronounced, effectively reducing dust accumulation, improving self-cleaning, and enhancing the antifouling and anti-flashover performance of the insulator.

High insulation performance: Through the three-skirt structure, umbrella rib design, and the application of semiconductor glaze, the creepage distance of the insulator is greatly increased, which can improve the insulation performance of the insulator while ensuring mechanical strength, giving it a good withstand voltage level under pollution conditions. It can effectively prevent creepage and flashover during operation and adapt to various operating conditions, especially in heavily polluted, high-altitude, and dry desert areas.

Reliable mechanical strength: Using high-strength toughened glass and high-quality metal accessories, bonded together with cement adhesive, it has high mechanical strength. At the same time, through optimized structural design, such as the grooves of the third umbrella rib and the concave-convex textures of the disc-shaped skirt, the connection stability between the components is further enhanced, capable of withstanding various external forces such as mechanical tension, wind, and vibration in power transmission lines, ensuring that the insulator will not be damaged by mechanical stress during long-term operation.

Product Advantages Like other toughened glass insulators, it has the characteristic of self-destruction at zero value. When defects or aging inside the insulator cause the insulation performance to drop to a certain level, the glass will automatically break, allowing operation and maintenance personnel to observe and detect it on the ground or from a helicopter, eliminating the need for pole-climbing inspection, reducing labor intensity, and saving line maintenance costs.

Application Scenarios Widely used in high-voltage overhead transmission lines of various voltage levels, especially in areas with harsh environmental conditions such as high dust, severe pollution, high altitude, and dry deserts, effectively improving the operational reliability of transmission lines and ensuring the safe and stable transmission of electricity.

 

Main Technical Parameters of Three-Umbrella Type (AC Type) Disc-type Suspension Toughened Glass Insulator (GB and IEC) 
The Parameters of Three-shells Type ( AC ) Toughened Glass Suspension Insulator(GB & IEC)

 

Insulator

Model

Drawing Number

Nominal

Diameter

D

(mm)

Structure

Height

H(mm)

Nominal

Creepage

Distance

L

(mm)

Connection

Mark

(mm)

Rated

Mechanical

Breaking 
Load

(kN)

Individual

Tensile

Load

Test(

kN)

Power

Frequency

Dry Withstand

Voltage

Power

(kV)

Dry Withstand

Voltage

Wet Withstand

Lightning

Impulse

Withstand

Voltage

Lightning

Voltage

Overvoltage

Withstand

Breakdown Withstand

(p.u.) 
Minimum Power

Impulse

Withstand

Voltage

Frequency Breakdown

Radio

10kV

Interference

1MHz( μ V)

Visible Corona

Voltage

Power

Arc

Experiment

Insulator

Single-piece weight

(kg)

UG160B170/550T 20R12330170550201608085501302.8130≤5018/220.12s/20kA8.0
UG210B170/550T 20R123301705502021010585501302.8130≤5018/220.12s/20kA10.2
UG300B195/550T 24R123301955502430015085501302.8130≤5018/220.12s/20kA11.3
UG300B195/635T 24R1238019563524300150100601302.8130≤5018/220.12s/20kA15.3
UG420B205/635T 28R1240020563528420210110651302.8130≤5018/220.12s/20kA16.5
UG550B240/550T 32R1240024063532550275110651302.8130≤5018/220.12s/20kA17.5


Main technical parameters of three-umbrella type (DC type) - disc-type suspended toughened glass insulator (GB and IEC) 
The Parameters of Three-shells Type ( DC ) Toughened Glass Suspension Insulator(GB &IEC)

 

Insulator

Model

Drawing Number

Nominal

Diameter

D

(mm)

Structure

Height

H(mm)

Nominal

Creepage

Distance

L

(mm)

Connection

Mark

(mm)

Rated

Mechanical

Breaking 
Load

(kN)

Individual

Tensile

Load

Test(

kN)

DC

Dry withstand

Withstand

Voltage

DC

Wet withstand

Withstand

Voltage

Wet Withstand

Lightning

Impulse

Withstand

Voltage

Lightning

Voltage

Overvoltage

Withstand

Breakdown Withstand

SF6

Breakdown

Withstand voltage

(KV)

Frequency Breakdown

Radio

10kV

Interference

DC visible electric

Visible Corona

Voltage

Insulator

Single-piece weight

(kg)

DCUG160B170/550T20R123301705502016080140551402.8210≤50≥508.9
DCUG210B170/550T20R1233017055020210105140551402.8210≤50≥5010.4
DCUG210B170/550T20R1233019555024300150150601402.8225≤50≥5011.3
DCUG300B195/635T24R1238019563524300150150601552.8225≤50≥5015.3
DCUG420B205/635T28R1240020563528420210150651552.8225≤50≥5017.5
DCUG550B240/635T32R1240024063532550275160701552.8225≤50≥5018.8

Product Recommendation

Online Message